Skip to main content Skip to main navigation

Publikation

Rotational Data Augmentation for Electroencephalographic Data

Mario Michael Krell; Su-Kyoung Kim
In: Proceedings of the 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC-17), July 11-15, JeJu Island, South Korea, Korea, Republic of, IEEE, 7/2017.

Zusammenfassung

For deep learning on image data, a common approach is to augment the training data by artificial new images, using techniques like moving windows, scaling, affine distortions, and elastic deformations. In contrast to image data, electroencephalographic (EEG) data suffers even more from the lack of sufficient training data. Methods: We suggest and evaluate rotational distortions similar to affine/rotational distortions of images to generate augmented data. Results: Our approach increases the performance of signal processing chains for EEG-based brain-computer interfaces when rotating only around y- and z-axis with an angle around 18 degrees to generate new data. Conclusion: This shows that our processing efficient approach generates meaningful data and encourages to look for further new methods for EEG data augmentation.

Projekte

Weitere Links